Pyrometer CellaCast PA 80

The CellaCast PA 80 was specially designed to measure the temperature of liquid metal at the runner of a blast furnace or cupola furnace. This pyrometer is also ideal for temperature detection where the molten metal is transferred from the melting or holding furnace to the pouring ladle.

Features:

  • Temperature range 750 – 2400 °C
  • Maintenance-free, wear-free system for temperature measurement at the melting furnace, holding furnace, cupola furnace and blast furnace
  • ATD function filters out temperatures detected from surfaces free of slag and oxide
  • Dual-wavelength technique provides reliable temperature data despite dust and steam
  • High-resolution optics enable viewing at greater distances
  • Sighting options: through-the-lens sighting, laser spot light or video camera
Target sighting Measuring range Lens Focus area Distance ratio
through-the-lens laser spot light video camera
750 – 2400 °C PZ 20.01 0.4 m – ∞ 150 : 1
PZ 20.06 1.2 m – ∞ 240 : 1
Measurement parameters
Measuring range 750 – 2400 °C
Sensor Si/Si photo diode
Spectral range 0.95 / 1.05 µm
Response time t98 ≤ 10 ms (T > 950 °C)
Measurement uncertainty 1 % of temp. reading [°C]
Repeatability 2 K
Temperature coefficient 0.05 %/K
Resolution current output 0.2 K + 0.03 % of selected range
Resolution interface 0.1 K
Resolution display 1 K
Optical variants
Lenses Standard lens PZ 20.01: focusing 0.4 m – ∞
Telephoto lens PZ 20.06: focusing 1.2 m – ∞
Electrical parameters
Analog output 0(4) – 20 mA linear, switchable, scalable
Resistance ≤ 500 Ω
Analog input 0 – 10 V
Switching output 2 x Open Collector 24 V DC, ≤ 30 mA
Switching input 2 x to 24 V
Interface USB, RS 485
Power supply 24 V DC +10 % / -20 %
Current consumption ≤ 175 mA bei 24 V DC
Camera
Video output Composite PAL, 1 Vpp, 75 Ω
Features
Sighting option Through-the-lens-sighting, laser spot light, camera
Display 4-digit LED display red, digit-height 8 mm
Status display 2 x LED
Control elements 3 buttons
General parameters
Connection M12 thread 8-pin connection
Ambient temperature 0 – 65 °C
Storage temperature -20 – +80 °C
Permissible humidity 95 % r.H. max. (non-condensing)
Dimension Ø 65 mm x 220 mm (max. 277 mm)
Housing Stainless steel V2A (1.4305)
Protection class IP 65 acc. to DIN 40050
Weight approx. 0.9 kg
Adjustable parameters
Parameters Measuring range
Measured variable and scale of analog input and output signals
Smoothing filter
Memory operation mode
Hold time of the memory
Emissivity
Transmittance
Compensation of the reflected ambient radiation
Limits and operating mode of the alarm contacts
Parameters of the ATD function
Linearization function
Status display of the LEDs
Simulation of current and temperature
Temperature unit °C/°F
Measurement channel two-colour, single-colour 1 and single-colour 2
Threshold level of the contamination monitoring

in addition, for model with camera:
TBC function
White balance

Functions
Overtemperature signal if the internal temperature exceeds 80 °C the analog output shows a value > 20.5 mA
Service function Simulation of a measured value or a current signal
ATD-(Automatic Temperature Detection) function Automatic temperature detection at discontinuous processes
Scope of delivery
Pyrometer CellaTemp PA
Connection cable VK 02/A (5 m)
Video cable VK 02/F (5 m) for model with built-in camera
USB cable VK 11/D (1.8 m)
Software CellaView
Manual (short)
Software
CellaView
  • molten metal at the melting furnace