The CellaCombustion PA 47 is a special pyrometer for non-contact temperature measurement of sooty flames in coal power plants or waste incineration plants. The measurement and signal processing based on the two-colour method detects the heat radiation of the sooty particles of the flame in the near infrared region at two wavelengths. The burn-out operation can be optimized by the flame temperature, the pollutant emission can be reduced and the slagging of the walls in the combustion chamber can be minimized.
Features:
- Range: 700 to 1700 °C
- Focusable optics for precise distance adjustment
- Precision lenses with broadband antireflection coating
- LED display is easy to read from a distance
- Test current can be applied to perform diagnostics
- as standard: digital input / output, two analogue outputs and USB / RS485 interface
Target sighting | Measuring range | Lens | Focus area | Distance ratio | |
---|---|---|---|---|---|
through-the-lens | video camera | ||||
700 – 1700 °C | PZ 20.01 | 0.4 m – ∞ | 80 : 1 |
Measurement parameters | |
---|---|
Measuring range | 700 – 1700 °C |
Sensor | Si/Si photo diode |
Spectral range | 0,8 / 1,05 µm |
Response time t98 | ≤ 20 ms (T>650 °C) ≤ 10 ms (T>750 °C) |
Measurement uncertainty | 1 % of temp. reading [°C] |
Repeatability | 2 K |
Temperature coefficient | 0.05 %/K |
Resolution current output | 0.2 K + 0.03 % of selected range |
Resolution interface | 0.1 K |
Resolution display | 1 K |
Electrical parameters | |
Analog output | 0(4) – 20 mA linear, switchable, scalable |
Resistance | ≤ 500 Ω |
Analog input | 0 – 10 V |
Switching output | 2 x Open Collector 24 V DC, ≤ 30 mA |
Switching input | 2 x to 24 V |
Interface | USB, RS 485 |
Power supply | 24 V DC +10 % / -20 % |
Current consumption | ≤ 175 mA bei 24 V DC |
Camera | |
Video output | Composite PAL, 1 Vpp, 75 Ω |
Features | |
Sighting option | Through-the-lens-sighting, laser spot light, camera |
Display | 4-digit LED display red, digit-height 8 mm |
Status display | 2 x LED |
Control elements | 3 buttons |
General parameters | |
Connection | M12 thread 8-pin connection |
Ambient temperature | 0 – 65 °C |
Storage temperature | -20 – +80 °C |
Permissible humidity | 95 % r.H. max. (non-condensing) |
Dimension | Ø 65 mm x 220 mm (max. 277 mm) |
Housing | Stainless steel V2A (1.4305) |
Protection class | IP 65 acc. to DIN 40050 |
Weight | approx. 0.9 kg |
Adjustable parameters | |
Parameters | Measuring range Measured variable and scale of analog input and output signals Smoothing filter Memory operation mode Hold time of the memory Emissivity Transmittance Compensation of the reflected ambient radiation Limits and operating mode of the alarm contacts Parameters of the ATD function (optinal) Linearization function Status display of the LEDs Simulation of current and temperature Temperature unit °C/°F Measurement channel two-colour, single-colour 1 and single-colour 2 Threshold level of the contamination monitoring Soot factor in addition, for model with camera: |
Functions | |
Overtemperature signal | if the internal temperature exceeds 80 °C the analog output shows a value > 20.5 mA |
Service function | Simulation of a measured value or a current signal |
ATD-(Automatic Temperature Detection) function | Automatic temperature detection at discontinuous processes |
Scope of delivery | |
Pyrometer CellaCombustion PA Connection cable VK 02/A (5 m) Video cable VK 02/F (5 m) for model with built-in camera USB cable VK 11/D (1.8 m) Software CellaView Manual (short) |
|
Software | |
CellaView |
- sooty flames