Pyrometer CellaTemp® PA 10

CellaTemp® PA 10 is a digital pyrometer for detecting temperatures of primarily non-metal objects in a range from 0 to 1000 °C. The wide-range temperature sensor provides versatility for a variety of applications. The target can be focused either by through-the-lens sighting or with an LED spot light for target marking. The pyrometer features a rear panel display and keypad. The bright 4-digit LED display is well visible from a distance. In the normal operating mode the display indicates the current temperature reading. The display will also show parameter adjustments made using the keypad.

Features:

  • Range:  0 to 1000 °C
  • Digital input / output
  • Focusable, interchangeable optics allow for precise distance adjustment
  • Precision lenses with broadband antireflection coating
  • LED display is easy to read from a distance
  • Test current can be applied to perform diagnostics
  • Signal processing: two analogue outputs and USB / RS485 interface.
Target sighting Measuring range Lens Focus area Distance ratio
through-the-lens laser spot light video camera
0 – 1000 °C PZ 10.01 0.3 m – ∞ 50 : 1
PZ 10.05 0.15 – 0.3 m 48 : 1
Measurement parameters
Measuring range 0 – 1000 °C
Sensor Thermopile
Spectral range 8 – 14 µm
Response time t98 ≤ 30 ms
Measurement uncertainty 1 % of temp. reading [°C], min. 2 K
Repeatability 1 K
Temperature coefficient 0.1 K/K (T < 250 °C)
0.04 %/K (T > 250 °C)
Resolution current output 0.2 K + 0.03 % of selected range
Resolution interface 0.1 K
Resolution display 0.1 K < 200 °C
1 K ≥ 200 °C
Optical variants
Lenses Standard lens PZ focusing 0.3 m – ∞
Close-up lens PZ 10.05: focusing 0.15 m – 0.3 m
Electrical parameters
Analog output 0(4) – 20 mA linear, switchable, scalable
Resistance ≤ 500 Ω
Analog input 0 – 10 V
Switching output 2 x Open Collector 24 V DC, ≤ 30 mA
Switching input 2 x to 24 V
Interface USB, RS 485
Power supply 24 V DC +10 % / -20 %
Current consumption ≤ 175 mA bei 24 V DC
Camera
Video output Composite PAL, 1 Vpp, 75 Ω
Features
Sighting option Through-the-lens-sighting, laser spot light, camera
Display 4-digit LED display red, digit-height 8 mm
Status display 2 x LED
Control elements 3 buttons
General parameters
Connection M12 thread 8-pin connection
Ambient temperature 0 – 65 °C
Storage temperature -20 – +80 °C
Permissible humidity 95 % r.H. max. (non-condensing)
Dimension Ø 65 mm x 220 mm (max. 277 mm)
Housing Stainless steel V2A (1.4305)
Protection class IP 65 acc. to DIN 40050
Weight approx. 0.9 kg
Adjustable parameters
Parameters Measuring range
Measured variable and scale of analog input and output signals
Smoothing filter
Memory operation mode
Hold time of the memory
Emissivity
Transmittance
Compensation of the reflected ambient radiation
Limits and operating mode of the alarm contacts
Parameters of the ATD function (optinal)
Linearization function
Status display of the LEDs
Simulation of current and temperature
Temperature unit °C/°Fin addition, for model with camera:
TBC function
White balance
Functions
Overtemperature signal if the internal temperature exceeds 80 °C the analog output shows a value > 20.5 mA
Service function Simulation of a measured value or a current signal
ATD-(Automatic Temperature Detection) function Automatic temperature detection at discontinuous processes
Scope of delivery
Pyrometer CellaTemp PA
Connection cable VK 02/A (5 m)
Video cable VK 02/F (5 m) for model with built-in camera
USB cable VK 11/D (1.8 m)
Software CellaView
Manual (short)
Software
CellaView
  • plastics
  • organic materials
  • rubber
  • paper
  • varnishes
  • food
  • coated metals
  • cement
  • asphalt