CellaTemp® PA 29 is a digital pyrometer for detecting temperatures ranging from 150 to 2000 °C. CellaTemp® PA 29 was specially designed to detect the temperature of shiny reflective metal objects at low temperatures.
Features:
- Range: 150 to 2000 °C
- Digital input / output
- Focusable optic allow for precise distance adjustment
- Precision lenses with broadband antireflection coating
- LED display is easy to read from a distance
- Test current can be applied to perform diagnostics
- Signal processing: two analogue output and USB / RS485 interface
Target sighting | Measuring range | Lens | Focus area | Distance ratio | ||
---|---|---|---|---|---|---|
through-the-lens | laser spot light | video camera | ||||
150 – 800 °C | PZ 20.08 | 0.3 m – ∞ | 48 : 1 | |||
250 – 2000 °C | PZ 20.01 | 0.4 m – ∞ | 210 : 1 | |||
PZ 20.03 | 0.2 – 0.4 m | 200 : 1 | ||||
PZ 20.06 | 1.2 m – ∞ | 310 : 1 | ||||
PZ 20.05 | 0.2 m – ∞ | 55 : 1 | ||||
180 – 1200 °C | PZ 20.01 | 0.4 m – ∞ | 60 : 1 | |||
PZ 20.03 | 0.2 – 0.4 m | 56 : 1 | ||||
PZ 20.06 | 1.2 m – ∞ | 96 : 1 |
Measurement parameters | |
---|---|
Measuring range | 150 – 2000 °C in several segments |
Sensor | Photo diode |
Spectral range | 1.8 – 2.2 µm |
Response time t98 | Measuring range 150 – 800 °C: ≤ 50 ms (T > 150 °C) ≤ 15 ms (T > 200 °C) ≤ 2 ms (T > 350 °C) Measuring range 180 – 1200 °C: Measuring range 250 – 2000 °C: |
Measurement uncertainty | Measuring range 150 – 800 °C and 180 – 1200 °C: 0.75 % of temp. reading [°C], min. 5 K Measuring range 250 – 2000 °C: |
Repeatability | 1 K |
Temperature coefficient | 0.25 K/K (T < 500 °C) 0.05 %/K (T > 500 °C) |
Resolution current output | 0.2 K + 0.03 % of selected range |
Resolution interface | 0.1 K |
Resolution display | Measuring range 150 – 800 °C and 180 – 1200 °C: 0.1 K < 200 °C 1 K ≥ 200 °C Measuring range 250 – 2000 °C: |
Optical variants | |
Lenses | Measuring range 150 – 800 °C: Objektiv F50 PZ 20.08: Fokussierung 0,3 m – ∞ Measuring range 180 – 1200 °C: Measuring range 250 – 2000 °C: |
Electrical parameters | |
Analog output | 0(4) – 20 mA linear, switchable, scalable |
Resistance | ≤ 500 Ω |
Analog input | 0 – 10 V |
Switching output | 2 x Open Collector 24 V DC, ≤ 30 mA |
Switching input | 2 x to 24 V |
Interface | USB, RS 485 |
Power supply | 24 V DC +10 % / -20 % |
Current consumption | ≤ 175 mA bei 24 V DC |
Camera | |
Video output | Composite PAL, 1 Vpp, 75 Ω |
Features | |
Sighting option | Through-the-lens-sighting, laser spot light, camera |
Display | 4-digit LED display red, digit-height 8 mm |
Status display | 2 x LED |
Control elements | 3 buttons |
General parameters | |
Connection | M12 thread 8-pin connection |
Ambient temperature | 0 – 65 °C |
Storage temperature | -20 – +80 °C |
Permissible humidity | 95 % r.H. max. (non-condensing) |
Dimension | Ø 65 mm x 220 mm (max. 277 mm) |
Housing | Stainless steel V2A (1.4305) |
Protection class | IP 65 acc. to DIN 40050 |
Weight | approx. 0.9 kg |
Adjustable parameters | |
Parameters | Measuring range Measured variable and scale of analog input and output signals Smoothing filter Memory operation mode Hold time of the memory Emissivity Transmittance Compensation of the reflected ambient radiation Limits and operating mode of the alarm contacts Parameters of the ATD function (optinal) Linearization function Status display of the LEDs Simulation of current and temperature Temperature unit °C/°F in addition, for model with camera: |
Functions | |
Overtemperature signal | if the internal temperature exceeds 80 °C the analog output shows a value > 20.5 mA |
Service function | Simulation of a measured value or a current signal |
ATD-(Automatic Temperature Detection) function | Automatic temperature detection at discontinuous processes |
Scope of delivery | |
Pyrometer CellaTemp PA Connection cable VK 02/A (5 m) Video cable VK 02/F (5 m) for model with built-in camera USB cable VK 11/D (1.8 m) Software CellaView Manual (short) |
|
Software | |
CellaView |
- aluminium
- bright, shiny metal surfaces
- laser applications