CellaTemp® PA 35 is a digital pyrometer for measuring temperatures ranging between 600 and 3000 °C. The short wavelength narrow band sensor works in a spectral region where neither sight path obstructions such dust or steam nor fluctuating emissivity will interfere with the measurement result. CellaTemp® PA 35 is especially suitable for detecting the temperature of metals (Tungsten, Molybdenum, etc.) and silicon wafers. CellaTemp® PA 35 features an integrated LED display, making it easy to view the temperature reading from a distance. Use the PC USB connection to set parameters such as emissivity and smoothing time constant or to perform diagnostics. Alternatively, emissivity can be set directly at the connection cable.
Features:
- Range: 600 to 3000 °C
- Focusable, interchangeable optics allow for precise distance adjustment
- Precision lenses with broadband antireflection coating
- Selective short-wavelength narrow-band spectral response
- Optimized to detect surface temperatures of metals and silicon wafers
- LED display is easy to read from a distance
- Test current can be applied to perform diagnostics
- Signal processing: two analogue outputs and USB / RS485 interface
Target sighting | Measuring range | Lens | Focus area | Distance ratio | ||
---|---|---|---|---|---|---|
through-the-lens | laser spot light | video camera | ||||
600 – 3000 °C | PZ 20.01 | 0.4 m – ∞ | 210 : 1 | |||
PZ 20.03 | 0.2 – 0.4 m | 200 : 1 | ||||
PZ 20.06 | 1.2 m – ∞ | 310 : 1 | ||||
PZ 20.05 | 0.2 m – ∞ | 55 : 1 | ||||
PA 20.06 | 0.6 m – ∞ | 430 : 1 |
Measurement parameters | |
---|---|
Measuring range | 600 – 3000 °C |
Sensor | Photo diode |
Spectral range | 0.82 – 0.93 µm |
Response time t98 | ≤ 50 ms (T > 650 °C) ≤ 2 ms (T > 850 °C) |
Measurement uncertainty | 0.3 % of temp. reading [°C], min. 4 K |
Repeatability | 1 K |
Temperature coefficient | 0.05 %/K |
Resolution current output | 0.2 K + 0.03 % of selected range |
Resolution interface | 0.1 K |
Resolution display | 1 K |
Optical variants | |
Lenses | Standard-Objektiv PZ 20.01: Fokussierung 0,4 m – ∞ Close-up lens PZ 20.03: focusing 0.2 m – 0.4 m Weitwinkel-Objektiv PZ 20.05: Fokussierung 0,2 m – ∞ Tele-Objektiv I PZ 20.06: Fokussierung 1,2 m – ∞ Telephoto lens II PA 20.06: focusing 0.6 m – ∞ |
Electrical parameters | |
Analog output | 0(4) – 20 mA linear, switchable, scalable |
Resistance | ≤ 500 Ω |
Analog input | 0 – 10 V |
Switching output | 2 x Open Collector 24 V DC, ≤ 30 mA |
Switching input | 2 x to 24 V |
Interface | USB, RS 485 |
Power supply | 24 V DC +10 % / -20 % |
Current consumption | ≤ 175 mA bei 24 V DC |
Camera | |
Video output | Composite PAL, 1 Vpp, 75 Ω |
Features | |
Sighting option | Through-the-lens-sighting, laser spot light, camera |
Display | 4-digit LED display red, digit-height 8 mm |
Status display | 2 x LED |
Control elements | 3 buttons |
General parameters | |
Connection | M12 thread 8-pin connection |
Ambient temperature | 0 – 65 °C |
Storage temperature | -20 – +80 °C |
Permissible humidity | 95 % r.H. max. (non-condensing) |
Dimension | Ø 65 mm x 220 mm (max. 277 mm) |
Housing | Stainless steel V2A (1.4305) |
Protection class | IP 65 acc. to DIN 40050 |
Weight | approx. 0.9 kg |
Adjustable parameters | |
Parameters | Measuring range Measured variable and scale of analog input and output signals Smoothing filter Memory operation mode Hold time of the memory Emissivity Transmittance Compensation of the reflected ambient radiation Limits and operating mode of the alarm contacts Parameters of the ATD function (optinal) Linearization function Status display of the LEDs Simulation of current and temperature Temperature unit °C/°F in addition, for model with camera: |
Functions | |
Overtemperature signal | if the internal temperature exceeds 80 °C the analog output shows a value > 20.5 mA |
Service function | Simulation of a measured value or a current signal |
ATD-(Automatic Temperature Detection) function | Automatic temperature detection at discontinuous processes |
Scope of delivery | |
Pyrometer CellaTemp PA Connection cable VK 02/A (5 m) Video cable VK 02/F (5 m) for model with built-in camera USB cable VK 11/D (1.8 m) Software CellaView Manual (short) |
|
Software | |
CellaView |
- precise measurement of metals
- semiconductors